GreenDrill control terminal 5.2
78
GreenDrill BAH0108-0 03.20
Fault
Possible fault elimination
Seeding shaft rotates
in transport position
Change the lifting unit signal
(see section "Entry of the working position sensor signal
source", page 90)
Seeding shaft does not rotate
in working position
Switch on the seeding shaft and start driving
Check the speed signal
Change the lifting unit signal
(see section "Entry of the working position sensor signal
source", page 90)
Low level sensor
without alarm message
Check the plug and cable
Change the intensity of the sensor
(see section 5.5, page 46).
Low level sensor
with continuous alarm
Realign the low level sensor
Change the intensity of the sensor
(see section 5.5, page 46)
Speed signal
is missing
Check the settings for the speed sensor
(see section 7, page 86)
Check the labels and connections
of the splitter
Test whether the speed signal is received on the control
terminal, if the speed sensor is not connected to the splitter
but rather to the control terminal.
If signals are received, replace the defective splitter.
Lifting unit signal
is missing
Check whether the sensor and magnets are opposite to each
other in the end position
Check the sensor settings (see section 7, page 86)
Check the connections and labels on the splitter
Test whether the lifting unit signals are received on the control
terminal, if the lifting unit signal sensor is not connected to the
splitter but rather to the control terminal.
If signals are received, replace the defective splitter.
The control terminal cannot
be switched on
Check the plug and power cable
Check the fuse
Check the battery
Check the connections of the battery cable (if equipped) (see
section 6.18.3.2,
page
81).
The control terminal is
switched off when the fan or
seeding shaft motor is
switched on
Check the battery voltage
Check the contacts
Power cable plug
Implement cable plug
Содержание GreenDrill GD200-E
Страница 2: ......
Страница 32: ...Structure and function 32 GreenDrill BAH0108 0 03 20 4 1 1 6 Seed metering wheel table ...