GreenDrill control terminal 5.2
62
GreenDrill BAH0108-0 03.20
20. Weigh the collected seed.
21. Select the display with the
buttons.
22. Confirm the selection with the
button.
23. Enter the weight [kg] of the collected seed on the control
terminal using the
buttons (e.g. 3.25 kg).
24. Confirm the entry with the
button.
The required seeding shaft speed is calculated
automatically.
The theoretical seeding shaft speed is calculated from the initial
data (working width and forward speed). If the calibrated
seeding shaft speed deviates by more than 3%,
the adjacent display appears.
the calibration must be repeated.
Display after correctly terminated calibration test
If no button is pressed, the display switches to the Main menu
after approx. 5 seconds. (see page 54).
6.6.2.1
Conversion of the seed rate [grains/m
2
] in [kg/ha]
Seed rate [kg/ha]
=
TGW [g] x grains/m
2
Germination capacity [%]
6.6.3
Seed calibration button
The calibration button (1) serves for starting the
seed calibration test and for emptying the seed
hopper.
The seeding shaft starts rotating when the
calibration button is pressed. The seeding shaft
rotates as long as the calibration button is
pressed.
During the seed calibration test, the running time
of the seeding shaft is automatically included in
the calculation.
The calibration button is attached to the
implement with magnets.