Kinetix 350 Drive Connector Data
AC Input Power Connector Pinout
Back-up Power Connector Pinout
Shunt Resistor and DC Bus Connector Pinout
Motor Power Connector Pinout
IPD
Designator
Description
(2097-V31PR
x
-LM
drives)
Signal
IPD
Designator
Description
(2097-V32PR
x
-LM drives)
Signal
L2/N
AC power in (non-doubler operation)
L2/N
L2
AC power in
L2
L1
AC power in
L1
L1
AC power in
L1
N
AC power neutral (only 120V doubler)
N
PE
Protective earth (ground)
PE
PE
Protective earth (ground)
PE
IPD
Designator
Description
(2097-V33PR
x
-LM, and 2097-
V34PR
x
-LM drives)
Signal
L3
AC power in (three-phase models)
L3
L2
AC power in
L2
L1
AC power in
L1
PE
Protective earth (ground)
PE
BP
Designator
Description
Signal
+24V
Positive 24V DC
+24V DC
-24V
24V DC power supply return
Return
BC
Designator
Description
Signal
+
Positive DC bus and shunt resistor
+
+
+
SH
Shunt resistor
SH
-
Negative DC bus
-
-
-
MP
Designator
Description
Signal
PE
Protective earth (ground)
PE
W
Motor power out
W
V
Motor power out
V
U
Motor power out
U
Содержание Kinetix 350
Страница 4: ...4 Rockwell Automation Publication 2097 UM002D EN P April2017 Summary of Changes Notes ...
Страница 50: ...50 Rockwell Automation Publication 2097 UM002D EN P April2017 Chapter 3 Kinetix 350 Drive Connector Data Notes ...
Страница 154: ...154 Rockwell Automation Publication 2097 UM002D EN P April2017 Appendix C Leakage Current Specifications Notes ...
Страница 159: ...Rockwell Automation Publication 2097 UM002D EN P April2017 159 Index Notes ...
Страница 160: ...160 Rockwell Automation Publication 2097 UM002D EN P April2017 Index ...
Страница 161: ......