Rockwell Automation Publication 2097-UM002D-EN-P - April 2017
81
Configure and Start up the Kinetix 350 Drive System
Chapter 5
Configure the Kinetix 350
Drive Ethernet IP Address
This section offers guidance on how to configure your Ethernet connection to
the Kinetix 350 drive.
Ethernet Connection
Configuration, programming, and diagnostics of the Kinetix 350 drive are
performed over the standard 10/100 Mbps Ethernet communication port by
using the Studio 5000 Logix Designer® application.
The Kinetix 350 drive and your personal computer must be configured to
operate on the same Ethernet network. The IP addresses of the Kinetix 350
drive, the personal computer, or both drive and personal computer can require
configuring to enable Ethernet communication between the two devices.
Kinetix 350 Drive Ethernet Port Configuration
The IP address of the Kinetix 350 drive is composed of four suboctets that are
separated by three dots to conform to the Class C Subnet structure. Each
suboctet can be configured with number from 1 to 254. As shipped from the
factory the default IP address of a drive is 192.168.124.200.
There are two methods of changing the current IP address. An address can be
assigned to the drive automatically (dynamic IP address) when the drive is
connected to a DHCP (Dynamic Host Configuration Protocol) enabled
server, or you can manually assign an IP address to the drive (static IP address).
Both methods of configuring the drive’s IP address are shown here.
Obtain the Kinetix 350 Drives’ Current Ethernet Settings
The current Ethernet setting and IP address of the Kinetix 350 drive can be
obtained from the drive display and keypad. Press
on the display and
use
to access parameters IP_1, IP_2, IP_3, and IP_4. Each of these
parameters contains one suboctet of the full IP address, for example, if the
drive default (factory set) address parameters:
• IP_1 = 192
• IP_2 = 168
• IP_3 = 124
• IP_4 = 200
IMPORTANT
Any changes that are made to the Ethernet communication settings on the
Kinetix 350 drive do not take effect until the drive is powered off and
powered on again. Until the power is cycled, the drive continues to use its
previous settings.
Содержание Kinetix 350
Страница 4: ...4 Rockwell Automation Publication 2097 UM002D EN P April2017 Summary of Changes Notes ...
Страница 50: ...50 Rockwell Automation Publication 2097 UM002D EN P April2017 Chapter 3 Kinetix 350 Drive Connector Data Notes ...
Страница 154: ...154 Rockwell Automation Publication 2097 UM002D EN P April2017 Appendix C Leakage Current Specifications Notes ...
Страница 159: ...Rockwell Automation Publication 2097 UM002D EN P April2017 159 Index Notes ...
Страница 160: ...160 Rockwell Automation Publication 2097 UM002D EN P April2017 Index ...
Страница 161: ......