Chapter 3
Safe Torque-off Connector Pinout
The Kinetix 350 drive ships with the (6-pin) wiring-plug header that connects
your safety circuit to the Kinetix 350 drive safe torque-off (STO) connector. If
your system does not use the safe torque-off feature, follow instructions in
starting on
to wire the drive with motion-
allowed jumpers.
Figure 11 - Safe Torque-off Connector
Table 13 - Kinetix 350 Drive Safe Torque-off Connector Pinout
1 2 3 4 5 6
+24 V DC c
ontrol
Contr
ol COM
Safety
status
Safety
input 1
Safety
COM
Safety
input 2
Bottom view of the Kinetix 350 drive.
(2097-V33PR5-LM drive is shown)
Wiring Plug Header
Safe Torque-off
(STO) Connector
STO Pin
Description
Signal
1
+24V DC output from the drive
+24V DC control
2
+24V DC output common
Control COM
3
Safety status
Safety Status
4
Safety input 1 (+24V DC to enable)
Safety Input 1
5
Safety common
Safety COM
6
Safety input 2 (+24V DC to enable)
Safety Input 2
IMPORTANT
Use only pins STO-1 (+24V DC Control) and STO-2 (Control COM) of the
motion-allowed jumpers to enable the drive when the safe torque-off
function is not used. When the safe torque-off function is in operation, the
24V supply must come from an external source.
Содержание Kinetix 350
Страница 4: ...4 Rockwell Automation Publication 2097 UM002D EN P April2017 Summary of Changes Notes ...
Страница 50: ...50 Rockwell Automation Publication 2097 UM002D EN P April2017 Chapter 3 Kinetix 350 Drive Connector Data Notes ...
Страница 154: ...154 Rockwell Automation Publication 2097 UM002D EN P April2017 Appendix C Leakage Current Specifications Notes ...
Страница 159: ...Rockwell Automation Publication 2097 UM002D EN P April2017 159 Index Notes ...
Страница 160: ...160 Rockwell Automation Publication 2097 UM002D EN P April2017 Index ...
Страница 161: ......