Rockwell Automation Publication 2097-UM002D-EN-P - April 2017
127
Troubleshoot the Kinetix 350 Drive
Chapter 7
Fc14
Excessive Current Feedback Offset
Current in one or more phases have been lost or remains below a preset
level.
Disable/Coast
Fc26
Runtime Error
Runtime Assertions have been detected.
Disable/Coast
Fc63
Product Specific
Product Specific (exotic) exceptions by Sub Code.
Disable/Coast
A node fault is a fault that impacts the whole drive.
Table 60 - Drive Behavior, nF
xx
Node Fault Codes
Four-digit Display
Name
Description
Best Stopping Method
nF01
Control Connection Update Fault
The Control Connection Update Fault code is used to indicate that updates
from the controller over the controller to drive connection have been
excessively late as determined by the Controller Update Delay High Limit
attribute value.
Disable/Coast
nF02
Processor Watchdog Fault
The Processor Watchdog Fault code indicates that the processor that is
associated with the device node has experienced an excessive overload
condition that has tripped the associated processor watchdog
mechanism.
Disable/Coast
nF03
Hardware Fault
The Hardware Fault code indicates that the critical support hardware such
as the FPGA or ASIC associated with the device node has experienced a
fault condition. This fault occurs when the EPM module has been
removed.
Disable/Coast
nF04
Data Format Error
This fault code indicates that an error has occurred in the data format
between the controller and the device, such as a Format Revision
mismatch.
Disable/Coast
nF06
Control Connection Loss Fault
The Control Connection Loss fault code indicates that the Motion
controller to drive connection from the controller has timed out.
Disable/Coast
Table 59 - Drive Behavior, Fc
xx
Custom Fault Codes (Continued)
Four-digit Display
Exception
Description
Best Stopping Method
(Only Major Fault)
Содержание Kinetix 350
Страница 4: ...4 Rockwell Automation Publication 2097 UM002D EN P April2017 Summary of Changes Notes ...
Страница 50: ...50 Rockwell Automation Publication 2097 UM002D EN P April2017 Chapter 3 Kinetix 350 Drive Connector Data Notes ...
Страница 154: ...154 Rockwell Automation Publication 2097 UM002D EN P April2017 Appendix C Leakage Current Specifications Notes ...
Страница 159: ...Rockwell Automation Publication 2097 UM002D EN P April2017 159 Index Notes ...
Страница 160: ...160 Rockwell Automation Publication 2097 UM002D EN P April2017 Index ...
Страница 161: ......