Rockwell Automation Publication 2097-UM002D-EN-P - April 2017
29
Install the Kinetix 350 Drive System
Chapter 2
Cable Categories for Kinetix 350 Drive Components
This table indicates the zoning requirements of cables that are connected to the
Kinetix 350 drive components.
Table 11 - Kinetix 350 Drive Components
Noise Reduction Guidelines for Drive Accessories
See this section when mounting an AC line filter or shunt resistor module for
guidelines that are designed to reduce system failures that excessive electrical
noises cause.
AC Line Filters
If you are using a Bulletin 2090 line filter, mount the filter on the same panel as
the Kinetix 350 drive, and as close to the drive as possible.
Observe these guidelines when mounting your AC line filter:
• Good HF bonding to the panel is critical. For painted panels, refer to
the examples on
• Segregate input and output wiring as far as possible.
Wire/Cable
Connector
Zone
Method
Very
Dirty
Dirty
Clean
Ferrite
Sleeve
Shielded
Cable
L1, L2, L3 (unshielded cable)
IPD
X
U, V, W (motor power)
MP
X
X
B+-, B-, BR (shunt resistor)
BC
X
24V DC
BP
X
Control COM, 24V DC control, safety enable, and
feedback signals for safe-off feature
STO
X
Motor feedback
MF
X
X
Registration
IOD
X
X
Others
X
Ethernet
Port 1
X
X
Содержание Kinetix 350
Страница 4: ...4 Rockwell Automation Publication 2097 UM002D EN P April2017 Summary of Changes Notes ...
Страница 50: ...50 Rockwell Automation Publication 2097 UM002D EN P April2017 Chapter 3 Kinetix 350 Drive Connector Data Notes ...
Страница 154: ...154 Rockwell Automation Publication 2097 UM002D EN P April2017 Appendix C Leakage Current Specifications Notes ...
Страница 159: ...Rockwell Automation Publication 2097 UM002D EN P April2017 159 Index Notes ...
Страница 160: ...160 Rockwell Automation Publication 2097 UM002D EN P April2017 Index ...
Страница 161: ......