Rockwell Automation Publication 2097-UM002D-EN-P - April 2017
79
Configure and Start up the Kinetix 350 Drive System
Chapter 5
Status Indicators
The Kinetix 350 drive has four status indicators and a four-digit display on the
top front panel as shown
. These status indicators and the display are
used to monitor the system status, activity, and troubleshoot faults.
Figure 46 - Front Panel Display
Table 37 - Status Indicators
Status
Indicator
Function
Description
D
Data entry
Yellow status indicator flashes when changing.
N Network
state
Indicates the state of the Network. See
. The bicolored status indicator
shows red, green, or amber.
M
Module state
Indicates the state of the Network. See
. The bicolored status indicator
shows red, green, or amber.
A
Axis state
Indicates the state of the Network. See
. The bicolored status indicator shows
red, green, or amber.
Table 38 - Module State Status Indicator
Status Indicator
State
Off
Power off
Flash red/green
Drive self-testing
Flashing green
Standby
Solid green
Operational
Flashing red
Major recoverable fault
Solid red
Major unrecoverable fault
Содержание Kinetix 350
Страница 4: ...4 Rockwell Automation Publication 2097 UM002D EN P April2017 Summary of Changes Notes ...
Страница 50: ...50 Rockwell Automation Publication 2097 UM002D EN P April2017 Chapter 3 Kinetix 350 Drive Connector Data Notes ...
Страница 154: ...154 Rockwell Automation Publication 2097 UM002D EN P April2017 Appendix C Leakage Current Specifications Notes ...
Страница 159: ...Rockwell Automation Publication 2097 UM002D EN P April2017 159 Index Notes ...
Страница 160: ...160 Rockwell Automation Publication 2097 UM002D EN P April2017 Index ...
Страница 161: ......