Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
97
Configure the 1444 Dynamic Measurement Module
Chapter 3
General Page
Use the Module Definition General page to specify the high-level application
of the module. This page is also where the general measurement definitions for
the module and each channel are made. The selections that are made here are
used throughout the tool, including on other Module Definition pages and the
configuration pages, to guide further selections.
In configuration the relays are numbered as follows:
• 1444-DYN04-01RA onboard Relay: relay #0
• 1444-RELX00-04RB at address 0: relays #1...4
• 1444-RELX00-04RB at address 1: relays #5...8
• 1444-RELX00-04RB at address 2: relays #9...12
Figure 44 - The Module Definition General Page
IMPORTANT
If edits are made to the module configuration, all other configurations are
reset to their default values.
Содержание 1444-AOFX00-04RB
Страница 10: ...10 Rockwell Automation Publication 1444 UM001D EN P June 2018 Table of Contents Notes...
Страница 12: ...12 Rockwell Automation Publication 1444 UM001D EN P June 2018 Preface Notes...
Страница 198: ...198 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 5 Configure the Tachometer Expansion Module Notes...
Страница 210: ...210 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 7 Configure Relays Notes...
Страница 230: ...230 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 8 Configure Alarms Notes...
Страница 240: ...240 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 9 Trend and Transient Capture Notes...
Страница 316: ...316 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 10 Operate the Module Notes...
Страница 549: ......