General Order Setup
For one byte, bit-wise control is used to allow for enabling individual tracking
filters and to assign a tacho channel.
Four 2-bit arrangements are used.
Bit
Description
0
Tracking filter 0
0: Enable; 1: Disabled
Default: Enabled
1
Tracking filter 0
0: Tacho 0; 1: Tacho 1
Default: Tacho 1
2
Tracking filter 1
0: Enable; 1: Disabled
Default: Enabled
3
Tracking filter 1
0: Tacho 0; 1: Tacho 1
Default: Tacho 1
4
Tracking filter 2
0: Enable; 1: Disabled
Default: Enabled
5
Tracking filter 2
0: Tacho 0; 1: Tacho 1
Default: Tacho 1
6
Tracking filter 3
0: Enable; 1: Disabled
Default: Enabled
7
Tracking filter 3
0: Tacho 0; 1: Tacho 1
Default: Tacho 1
Table 170 - Common Services
Service
Code
Implementation
Service Name
Description of Service
Class
Instance
0x0E
x
x
Get Attribute Single
Returns the contents of the specified attribute
Get requests to certain attributes require data to
be requested from the auxiliary module itself. If
that module is not present/active on the bus, an
embedded server error is returned in response to
the request.
Содержание 1444-AOFX00-04RB
Страница 10: ...10 Rockwell Automation Publication 1444 UM001D EN P June 2018 Table of Contents Notes...
Страница 12: ...12 Rockwell Automation Publication 1444 UM001D EN P June 2018 Preface Notes...
Страница 198: ...198 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 5 Configure the Tachometer Expansion Module Notes...
Страница 210: ...210 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 7 Configure Relays Notes...
Страница 230: ...230 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 8 Configure Alarms Notes...
Страница 240: ...240 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 9 Trend and Transient Capture Notes...
Страница 316: ...316 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 10 Operate the Module Notes...
Страница 549: ......