USER MANUAL – rev.2016/12
AGS 2500/3000 EN-HP
page
62
11.5
Operation description – manual control
In the manual control spraying is provide manually. Between work we can increase and
decrease the pressure and, in this context change hectare consumption, in short, the spraying
takes place without the operation of the computer or. without automatic control.
Using the keys and
opens the bypass valve
(last sectional valve), and each section, by using the buttons
we
regulate
the
working pressure.
Closing sectional valves:
By pressing the "MAIN" button, we open the bypass valve, at the same time - automatically
closes all distribution valves (sectional valves). Above the keys to individual sections, instead
of the red LED diode, turn on green LED diode. Green LED diode indicates that the key for
sectional valves is on, but section valves are not open.
Opening the sectional valves:
For open distribution valves require the inclusion of key "MAIN", through which
automatically open the distribution valves, closes bypass valve, over the keys of the
distribution valves lights up red LED diodes, green LEDs turn off.
In so far as the AG-TRONIK entered the correct constants for the speed sensor, flow sensor
and the working width, then you can monitor across the screen all the main parameters of
spray such as:
• hectare consumption;
• speed spray
• Working width
• cultivated area treated
• hectare efficiency
• completed trail
• the current flow
• Analysis.
Manual control can be performed when the AG-TRONIK is turned on, button
is
turned on (the red LED diode in the upper right corner button lights),
button is off
(does not light or not flashing LED in the upper right corner of the
key AUTO).
11.6
Operation description – automatic control
In automatic control, set hectare dosage is controlled by AG-TRONIK. Of course, all of the following
conditions must be met:
Correct choice of spraying parameters, such as correct choice of spraying speed, correct
choice of nozzles…;
Correct input of constants of flow and speed sensors;
Correct input of working width;
Ensure the following when spraying:
Correct choice of crop protection liquid
Correct calculation of concentration
Содержание AGS 2500 EN-HP
Страница 2: ......
Страница 8: ...VI...
Страница 10: ...VIII...
Страница 113: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 103 PARAMETER VALUE NOTE imp l d1 d2 d3 d4 d5 d6 d7 D Imp km l ha...
Страница 120: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 110 14 3 Dimensions and weight...
Страница 127: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 117 16 COMBINATION MATRIX 16 1 Combination matrix AGS 2500 EN HP...
Страница 128: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 118 16 2 Combination matrix AGS 3000 EN HP...
Страница 129: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 119 17 NOTES...
Страница 130: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 120...
Страница 131: ......