AGS 2500/3000 EN-HP
USER MANUAL – rev.2016/12
page
71
Correction:
Constant correction of flow sensor is the most accurate measurement. It is done, when the first
tank has been sprayed. The positive side of correction is that a measurement with chemical is
performed, therefore correct density of chemical is regarded, and the down side is that it can
only be executed, when the first tank is emptied.
Measurement starts before the start of spraying. At that time, daily counter of spray
consumption must be set to "0" (chapter PROGRAMMING, Erasing daily counters of spray
consumption [l], surface area [ha] and path [km]). Spraying follows. When complete (known)
capacity of chemical substance has been used, e.g. 400 l, and value 393 l is displayed on basic
readout under section l, correction must be performed. Follow the procedure below to perform
correction:
Select line CORRECTION and press key
to open the following window::
Following quantities are displayed:
current constant imp/l (711)
measured quantity (393)
actual quantity (393)
Actual quantity is selected and when you press key
, it starts to blink. Set measured
quantity with keys
and
. Once the quantity is set, press key
to display new
constant imp/l (698 imp/l).
Use button
to return to basic image of menu "FLOW CONSTANT".
Содержание AGS 2500 EN-HP
Страница 2: ......
Страница 8: ...VI...
Страница 10: ...VIII...
Страница 113: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 103 PARAMETER VALUE NOTE imp l d1 d2 d3 d4 d5 d6 d7 D Imp km l ha...
Страница 120: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 110 14 3 Dimensions and weight...
Страница 127: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 117 16 COMBINATION MATRIX 16 1 Combination matrix AGS 2500 EN HP...
Страница 128: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 118 16 2 Combination matrix AGS 3000 EN HP...
Страница 129: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 119 17 NOTES...
Страница 130: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 120...
Страница 131: ......