Performance Tests
3
Installation and Verification Manual
79
Now set
Clock Source
to
External
,
Format
to
DS1 Data
.
24
Connect the Test Set DS1 Transmit OUT port to the
OmniBER OTN Clock IN DS1 port using a Bantam cable.
Connect the OmniBER OTN’s DS1 Clock Out port to the Test
Set DS1 Receiver IN using a Bantam cable.
25
Set the PDH/DSn Test Set as follows:
TRANSMIT/RECEIVE settings to COUPLED
SIGNAL to DS1 rate
CLOCK to INTERNAL
OUTPUT LEVEL to DSX-1
LINE CODE to B8ZS
PAYLOAD TYPE to ESF UNSTRUCTURED