134
Installation and Verification Manual
3
Performance Tests
3
Connect the
52 Mb/s OUT
port to the Oscilloscope CHAN 1, using
the E2622A Termination Adapter Probe
.
4
Load the
STS1_ANSI_EYE.msk
test mask and check the eye meets
the mask. See examples
Adapter
54810A Oscilloscope
OmniBER OTN
CH1
STS-1/STM-0e Output
BNC to BNC cable
E2622A
75/50
Ω
STS-1/STM-0e Output
N O T E
It may be necessary to use Manual settings to Align this mask. If
necessary change the selection in the scope Mask Test Set-up to allow
manual settings rather than File Set-up for Alignment.