Self Test Overview
4
Installation and Verification Manual
155
Minimum test loopback requirements
Self Test
Optical Loopback
(15 dB attenuation
must be used)
Electrical
Loopback
DCC Loopback
plug
Loopbacks used are
dependent on
Options fitted
Only required
if Option 012
is installed.
• All tests
A, B, C, F
D
E
•
Confidence Test
A, B, C, F
D
not required
Confidence Tests
(10Gb/s Optics)
A
Confidence Tests
(2.5Gb/s - 52 Mb/s
Optics)
B, C
Confidence Tests
Unbalanced Electrical
Ports (52 Mb/s down
to DS3)
D
Confidence Tests(E1
Balanced Ports)
E
Confidence Tests (DS1
Balanced Ports)
F
•
Optical Power Test
A, B, C
not required
not required
•
DCC Add/Drop Test
A
not required
E
•
Frequency Test
A, B, C
D
not required
N O T E
If single wavelength optics are fitted to the 2.5 Gb/s - 52 Mb/s Optical Out
port then the Self Test should be performed twice to verify all the Optical In
ports. Perform the test with the 2.5 Gb/s-52 Mb/s Optical Out port
connected to the 2.5 Gb/s Optical In port and repeat with the
2.5 Gb/s-52 Mb/s Optical Out port connected to the 662-52 Mb/s Optical
In port. Select the cable configuration from the test menu as appropriate.
panther3_iv.book Page 155 Wednesday, January 15, 2003 12:03 PM
Содержание OmniBER J7230A
Страница 2: ...sdh_Lynx2 book Page 148 Wednesday April 17 2002 12 49 PM...
Страница 10: ...8 Installation and Verification Manual panther3_iv book Page 8 Wednesday January 15 2003 12 03 PM...
Страница 172: ...170 Installation and Verification Manual panther3_iv book Page 170 Wednesday January 15 2003 12 03 PM...
Страница 173: ...sdh_Lynx2 book Page 148 Wednesday April 17 2002 12 49 PM...