162
Installation and Verification Manual
4
Self Test Overview
What to Do if the Self Test Fails
1
Check all connections to make sure that all the correct
loopback connections are in place and Optical Attenuators
are fitted as required.
2
Be suspicious of any optical interface failures and if
necessary clean all optical connections with a recognized
cleaning kit before retrying the Self Test.
3
If the problem persists then contact your local Agilent
Service Office or representative.
Tips and Checks to Confirm Correct Optical Loopback
•
Make sure connectors are located in key/notch of the port
connectors to ensure full insertion.
•
Check Transmitter and Receiver are set to the same Signal
Rate and that the correct Laser is On when test is being Run.
•
Press
<Smart Test>
, choose
Shortcuts > Optical Power
then
press
<Select>
. Check the Received signal level is in the
Green BER measurement power range.
•
Ensure all optical connections are clean and fully connected
with no sharp bends or twists in the optical patch cord.
Check the Optical Cord and Attenuator are not damaged
and/or substitute with equivalent
To check self test failures
panther3_iv.book Page 162 Wednesday, January 15, 2003 12:03 PM