118
Installation and Verification Manual
3
Performance Tests
1
Recall the OmniBER OTN’s default settings as shown on
2
Press
<Menu>
, select
Tx/Rx > Transmitter
and set the
Signal Mode
to
PDH/DSn
. Now set the
Signal Rate
to
2Mb/s, Termination 120 ohm (Bal)
.
3
Connect the
2 Mb/s BAL OUT
port to the Oscilloscope CHAN
1, using the E2621A Termination Adapter Probe, set probe
switch to
120
Ω.
N O T E
The DS1-LO Pulse mask test is not applicable to step 6 and the check is
included to provide a functional confirmation of the LO selection.
To test the 2 Mb/s balanced output pulse mask
panther3_iv.book Page 118 Wednesday, January 15, 2003 12:03 PM