Chapter 16
387
GPIB Command Reference
OUTPMKR?
16. GPI
B
Com
m
an
d Re
fe
re
nce
( O -
R )
OUTPMKR?
Syntax
OUTPMKR?
Description
For the active trace (set with the “TRAC” command on page 457), reads out the
measurement parameter value and sweep parameter value at the marker position. If the
marker function is off, executing this command causes an error and the read out values are
invalid.(Query only)
Query response
{numeric 1},{numeric 2},{numeric 3}<newline><^END>
Readouts are as follows:
{numeric 1}:
Readout of the measurement parameter value at the marker position. If
the measurement parameter is a scalar value (for other than
COMPLEX Z-Y), the measurement parameter value is read out. If the
measurement parameter is a vector value (for COMPLEX Z-Y), the
readout is as follows:
•
If the polar chart format is selected, the amplitude is read out.
•
If the complex plane format is selected, resistance (for trace A) or
conductance (for trace B) is read out.
{numeric 2}:
Subsidiary readout of the measurement parameter value at the marker
position. If the measurement parameter is a scalar value (for other than
COMPLEX Z-Y), 0 is always read out. If the measurement parameter
is a vector value (for COMPLEX Z-Y), the readout is as follows:
•
If the polar chart format is selected, the phase is read out.
•
If the complex plane format is selected, reactance (for trace A) or
susceptance (for trace B) is read out.
{numeric 3}:
Sweep parameter value at the marker position.
Corresponding
key
No front panel key is available to execute this function.
Содержание 4294A
Страница 4: ...4 ...
Страница 18: ...18 Contents ...
Страница 24: ...24 Chapter1 To make effective use of this manual Other manuals attached to this unit ...
Страница 94: ...94 Chapter6 Reading Writing Measurement Data Reading Writing Data ...
Страница 110: ...110 Chapter7 Processing Measurement Results Analyzing Measurement Results ...
Страница 130: ...130 Chapter9 Communication with External Equipment Using the I O Ports Sample Program to Use the I O Port ...
Страница 136: ...136 Chapter10 Handling Errors Sample program for error handling ...
Страница 246: ...246 13 Application Sample Programs File Transfer Function ...
Страница 254: ...254 Chapter15 Setting the Display LCD Sample program for setting the LCD screen ...
Страница 507: ...Index Index 507 Index ...
Страница 508: ...508 Index Index ...
Страница 509: ...Index Index 509 Index ...
Страница 510: ...510 Index Index ...
Страница 511: ...Index Index 511 Index ...
Страница 512: ...512 Index Index ...
Страница 513: ...Index Index 513 Index ...
Страница 514: ...514 Index Index ...
Страница 515: ...Index Index 515 Index ...
Страница 516: ...516 Index Index ...
Страница 517: ...Index Index 517 Index ...
Страница 518: ...518 Index Index ...