2/2
C 10
Operating mode
G 01065 - Edition 06 - December 06
Remote control via
RS 232/485 serial link
Pump alone or
in a group of pumps
The pump is monitored by the equipment in which it is installed, either
alone or in a group of pumps.
It is remote controlled by the commands transmitted on the serial link
(see
B 110
).
Commands and reception syntax are given in chapter
C 90
.
The remote mode dry contacts have the priority over the serial link
mode.
Control Remote selection
(J14-S1 contact, see
B 100
)
Priority over
Remote control mode
(REM)
Remote control connector > RS232
Local mode
(LOC)
RS232 > Hand Held Display Module
Remote controlled
operating modes
Remote control via J 14
(Dry contacts)
Pump alone
The pump is monitored by the equipment in which it is installed (such
as an automated pumping system or an industrial equipment).
The pump is remote controlled by dry contacts wired on J 14
connector or direct voltage (see70).
The hand-held remote control keyboard is inhibited as long as the
contact S1 of the J 14 connector (see
B 70
) is kept open.
In Remote mode,
”REM”
is displayed on the display.
Datas and operating parameters can be read locally on the hand-held
remote control.
Emergency pump can be externally monitored by using J1 connector
pins 2 and 3 (see
B 100
).
adixen Vacuum Products - Operating instructions - ADP/ADS Series Two