background image

Specifications Information and Repair Parts Manual  

     

547X, 548X & 549X Series

                                                

5470-250-00

1

1/2020

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate 

or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating 

Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions 

for future reference.  AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.

©2020  AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so 

voids warranty.

Stainless Steel Straight 

Centrifugal Pumps

Refer to pump manual 1808-634-00 for General Operating and Safety Instructions.

ASSEMBLY

 

MOTOR (FOR UNITS SHIPPED WITHOUT DRIVER ONLY) 

(Refer to Figure 1) 

If any parts are missing or damaged, do not attempt to assemble or 
operate pump until repair parts are obtained and properly installed.

 
1. 

Verify that motor conforms to ALL standards specified in “Description”, 

and is equipped with slinger washer not included with pump.

2.  Place motor in vertical position with shaft end up. Set adapter (Ref. No. 

2) on top of motor. 

NOTE:

 Be sure to align adapter in desired position now. Rotating adapter 

allows pump discharge port to be positioned at various angles.
3. 

See “INSTALLATION OF NEW SEAL” under “Maintenance” section and 

follow steps to complete assembly of pump.

MAINTENANCE

 

 

Make certain that unit is disconnected from power source 

before attempting to service or remove any components!

 

SHAFT SEAL REPLACEMENT

(Refer to Figure 1)

REMOVAL OF OLD SHAFT SEAL

1. 

Disconnect power supply and piping.

2.  Place unit in vertical position with pump end up.
3. 

Disassemble pump by removing fasteners and washers (Ref. Nos. 10 & 
11) which holds casing (Ref. No. 9) in place. Lift off casing and casing seal 

(Ref. No. 5).

4.  Unscrew impeller nut (Ref. No. 8), and impeller (Ref. No. 6) separately by 

turning each counterclockwise. Impeller seal (Ref. No. 7) will also be freed 
at this time. If seal head (Ref. No. 4 with spring) is retained on impeller, 
separate at this time.

NOTE:

 It may be necessary to use a soft hammer to tap outside of impeller in 

a counterclockwise direction to loosen it.

NOTE:

 Access to motor shaft is provided at end opposite pump (plug may need 

to be pried out or cover removed). Use screwdriver in slot or wrench on flats to 

keep motor shaft from turning.
5. 

Lift off casing cover (Ref. No. 3) while pulling seal along with it. Seal seat 

(without spring) can now be freed by pressing through from rear of casing 
cover.

IMPORTANT: Do not damage motor shaft, impeller stem or seal cavity in casing 

cover as this may cause leaks.

DESCRIPTION

AMT Stainless Steel Solids Handling  End Suction Centrifugal  pumps are designed  for continuous  duty high flow and high pressure applications including: 

chemical processing, liquid transfer, pressure boosting, circulating, dirty water. Constructed of rugged deep drawn stainless steel for durability and corrosion 

resistance. Investment cast stainless steel closed impeller for enhanced performance, and handles a maximum of 1/8” diameter solids. Handle liquids from 40̊ 
to 200̊ F (4̊ to 93̊ C) with standard Viton seals; 40̊ to 180̊ F (4̊ to 82̊ C) with optional Buna-N seals. Wetted parts include: Stainless Steel impeller and impeller 
nut; Stainless Steel casing and casing cover; Type 21 mechanical shaft seal comprised of carbon, ceramic and stainless steel components; and Viton seals 
(Buna-N seals Optional). High head units also include wetted Stainless Steel motor shaft. The discharge port on all models can be rotated 360̊ in 90̊ increments 
to accommodate specific applications.

Motorized units are direct coupled to a 3450 RPM motor (see “Specifications” for additional motor data). Single phase pump motors have automatic reset thermal 
protection. All models are manual mode and require field wiring, no controls are supplied. Check motor wiring before putting unit into operation (see motors 
nameplate for specific wiring diagram).

Содержание AMT 547 Series

Страница 1: ... up 3 Disassemble pump by removing fasteners and washers Ref Nos 10 11 which holds casing Ref No 9 in place Lift off casing and casing seal Ref No 5 4 Unscrew impeller nut Ref No 8 and impeller Ref No 6 separately by turning each counterclockwise Impeller seal Ref No 7 will also be freed at this time If seal head Ref No 4 with spring is retained on impeller separate at this time NOTE It may be nec...

Страница 2: ...ler 3 Carefully screw impeller back onto motor shaft by turning clockwise Be sure to snug up impeller by holding motor shaft as during disassembly Add impeller seal Ref No 7 then impeller nut Ref No 8 and tighten 4 Carefully lay casing seal Ref No 5 into desired position NOTE Casing may be rotated to position discharge port at various angles 5 Use fasteners and washers Ref Nos 10 11 to attach casi...

Страница 3: ... OF CHANGE REV ECO DATE BY REFERENCE FIRST USED DIMENSIONS IN INCHES mm AMTPUMPCOMPANY EXCEPT AS DRAWN BY DRAWING NUMBER TITLE APPROVED BY 1 2 ANGULAR 1 64 FRACTIONAL XXX 005 15 XX 010 30 NOTED DECIMAL ROYERSFORD PA 19468 SCALE ISSUE DATE DATE DATE TOLERANCES REV TM A Subsidiary of The Gorman Rupp Company 5487 98 Exploded View 1 5 3 6 2020 DHU NOT TO BE USED IN ANY THIS COMPANY WAY DETRIMENTAL TO ...

Страница 4: ...ncl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT 1 6 Impeller Kit 5475 010 98 5470 010 98 5480 010 98 5484 010 98 5484 010 98 5494 010 98 1 includes Ref Nos 6 and 8 7 Impeller O Ring Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT 1 8 Impeller Nut Incl w Ref 6 Incl w Ref 6 Incl w Ref 6 Incl w Ref 6 Incl w Ref 6 Incl ...

Страница 5: ...Specifications Information and Repair Parts Manual 547X 548X 549X Series 5470 250 00 5 1 2020 NOTES ...

Страница 6: ...Specifications Information and Repair Parts Manual 547X 548X 549X Series 5470 250 00 6 1 2020 NOTES ...

Страница 7: ...Specifications Information and Repair Parts Manual 547X 548X 549X Series 5470 250 00 7 1 2020 ...

Страница 8: ...Specifications Information and Repair Parts Manual 547X 548X 549X Series 5470 250 00 8 1 2020 www amtpump com ...

Отзывы: