M4 monitoring system function table
G 01074 - Edition 08 - Januar
y 10
ENTER
SETTING
Selection
Selection
Settings limits
Initial
configuration
SERIAL LINK 1
TYPE
RS232 / RS485 /
NETWORK M3 / NETWORK M4
RS 232
ECHO
ENABLED / DISABLED
ENABLED
SPEED
1200/2400/4800/9600 Bauds
9600
PARITY
NO / EVEN / ODD
NO
2 STOP BITS
ENABLED / DISABLED
DISABLED
ADDRESS
0 to 999
0
N2 FLOW SENSOR
WARNING time
0 to 60 mn / DISABLED
0 mn
ALARM time
0 to 60 mn / DISABLED
DISABLED
PURGE WARNING
(4)
(only with
MFS
)
0 to 60 slm (“P” version)
0 to 120 slm (“H” version)
15
ADP TEMPERATURE
(4)
INPUT VALUE
70 to 130°C (or 140°C: ADS 1802)
100
ALARM threshold
(5)
(Input value + 10°C ) to 140°C
120
AUX. TEMP SENSOR
(4)
WARNING threshold 1
0 to 140°C
DISABLED
(3)
WARNING threshold 2
20°C to 170°C
DISABLED
(3)
REGUL T° AUX
INPUT VALUE
70 to 100°C
100
ALARM threshold
(5)
(Input value + 10°C ) to 150°C
120
ADP POWER SENSOR
WARNING threshold
500 to 4000W
2500
ALARM threshold
(Warning threshold) to 5000W
4000
ANALOG INPUT
(4)
WARNING threshold
0 V to (Alarm threshold)
4000
ALARM threshold
(Warning threshold) to 9950 mV
8000
LOG1 SENSOR
(4)
WARNING time
0 to 60 mn / DISABLED
DISABLED
ALARM time
0 to 60 mn / DISABLED
DISABLED
LOG2 SENSOR
(4)
WARNING time
0 to 60 mn / DISABLED
DISABLED
ALARM time
0 to 60 mn / DISABLED
DISABLED
LOG3 SENSOR
(4)
WARNING time
0 to 60 mn / DISABLED
DISABLED
ALARM time
0 to 60 mn / DISABLED
DISABLED
PURGE FLOW PROLONGED
PURGE FLOW
PROLONGED
0 to 120 mn
10 mn
TIME - DATE
Month/Day/Year
Hours/Minutes
TEMPERATURE UNIT*
CELSIUS / FARHENHEIT
CELSIUS
PRESSURE UNIT*
mbar / PSI / Torr / hPa
mbar
CONTRAST*
Contrast display setting
(3) : ADS 602 P and H versions: see
C 20
for threshold adjustment.
(4) : Accessible menu only if option is validated in DEFINITION menu.
(5) : Alarm threshold setting must be done before the input value setting.
(*) : specific parameters to each hand-held remote control.