G 01043 - Editition 11 - September 14
1/6
A 40
Technical characteristics
Characteristics Units
ADP 122 P
ADP 122 LM
ADS 602 H
ADS 602 P
ADS 602 LM
ADS 1202 H
ADS 1202 P
ADS 1802 H
ADS 1802 P
Peak pumping speed
(50/60 Hz)
m
3
/h
95/112
480/560
1050/1150
1700/1700
cfm
55.8/65.8
282/329
617/676
1000/1000
l/mn
1583/1867
8000/9333
17500/19167
28333
Typical Ultimate Pressure
(without N
2
purge) (50/60 Hz)
mbar
1.10
-2
/9.10
-3
8.10
-4
/5.10
-4
8.10
-4
/5.10
-4
5.10
-4
mtorr
7.5 / 6.7
0.6 / 0.375
0.6 / 0.375
0.375
Pa
1 / 0.6
0.08 / 0.05
0.08 / 0.05
0.05
Maximum Ultimate Pressure
(without N
2
purge) (50/60 Hz)
mbar 3.10
-2
/1.5x10
-2
2.10
-3
/9.10
-4
2.10
-3
/9.10
-4
9.10
-4
torr
22.5 / 11.25
1.5 / 0.675
1.5 / 0.675
0.675
Pa
3 / 1.5
0.2 / 0 .09
0.2 / 0 .09
0 .09
Maximum pumped volume
m
3
1
Motor rating
kW
1.5
3
5.2
7.5
Supply voltage
V
200 V / 480 V - 3 phases - 50/60 Hz
(1)
Power consumption at ultimate
pressure (50/60 Hz)
kW
1.3 / 1.5
1.8 / 2.0
3.0 / 3.2
3.5
Maximum continuous inlet
pressure
mbar
50
10
5
3
torr
37
7.5
3.7
2.25
Maximum exhaust overpressure
mbar
1200
torr
900
N
2
flowrate range
(2)
slm
0 to 60 (P version) / 0 to 120 (H version)
20 to 70 «P»
0 to 120 «H»
Water flow
l/mn
min. 1
min. 1
min. 1.3
min. 5
Rotation speed
(functionnal block)
rpm
3000 to 3600
6000
Gear boxes
Dry pump
(3)
fluid capacity Roots
0.35
-
0.35
0.7
0.35
1.90
0.15
1.55
Inlet flange
DN 50 – ISO KF
DN 100 – ISO KF
Exhaust flange
DN 40 – ISO KF
Dimension (l x w x h)
mm
830 x 390 x 580
830 x 390 x 875
995 x 390 x 985
995 x 390 x 985
inch
32.7 x 15.4 x 22.8
32.7 x 15.4 x 34.4
39.2 x 15.4 x 38.8
39.2 x 15.35 x 38.8
Weight
kg
243
378
531
498
lbs
540
840
1170
1097
Maximum sound level
(4)
dB(A)
< 65
< 68
< 69
< 69
(1) According to CE regulations. ADP Series Two can withstand a supply voltage variation of ± 10 %.
(2) P and H versions only.
(3) A300 oil charge is filled at factory.
(4) Measured at 1 m length. and 1.6 m height. according to ISO 9614-2 standard.
adixen Vacuum Products - Operating instructions - ADP/ADS Series Two