Use of the serial link (M4 monitoring)
G 01078 - Edition 07 - December 06
Interpreting responses
supplied by
the serial link
OK or a specific response to the order if everything is correct.
ERR0 : setting fault
ERR1 : order fault
ERR2 : parameter fault
ERR3 : context fault
ERR4 : checksum fault
Note: “The Remote control mode“ has priority on RS 232 or RS 485
commands for SYS, ROO and PUR commands.
Modifying the
header character
Order
Paramater
Response
Action
HDR
<val>
val = decimalv
alue of the ASCII
code of the header
character between
001 and127
OK or ERR3
Change the header character in front of a response address.
Note :
- The factory configuration is the decimal code «035» of the
character «#».
- The code «020» corresponds to «no header character»
- Customer selection is memorized by the monitoring.
The value «047», the decimal ASCII code of the character «/».
Command
#002HDR047<CR>
Response
/0020K
Command
002IDN<CR>
Response
/002M3 MONITORING SYSTEM VERSION 2.02
Example: