The 6139 Keypad will display the following prompts, which are sent by the Long Range Radio transmitter to the control. Note:
These prompts are for the 7820 Radio only. If you are using a different radio, refer to the radio’s instructions for the
correct prompts.
DEVICE ADDRESS
Enter the device address of the radio. The default address is 3.
ID #
(1234)
Enter the 4-digit customer account number, 0001-9999. This ID number will appear in the
messages generated by the radio. Messages generated by the panel and transmitted by
the radio will contain the ID number programmed into the panel. The radio and the panel
should have the same ID number, if possible.
If a different 4-digit customer account number is used in the radio than is programmed into the alarm control,
the radio will transmit radio-specific messages (power-on reset, AC fail, etc.) using the radio customer
number, and alarm messages using the control panel’s customer number. If these numbers are different,
you will be billed for two AlarmNet radio accounts.
ODD [Y/N]
(N)
Enter Y for odd system flag; N for even system flag.
Alarmnet (Y/N)
(Y)
Enter Y if an AlarmNet installation. Enter N for private system users (skip to Question 7).
CS ID
(11)
Enter the primary central station’s system ID number, 1-7F (will not be displayed for private
system users).
BAT PRESENT [Y/N]
(N)
Enter Y if optional battery will be used. Must be Y for UL installations (a battery must be
installed).
USE RADIO # [Y/N]
(N)
If Y is selected, the Radio ID number will replace the panel Subscriber ID in panel-
generated messages with the Radio ID number.
If N is selected, the radio will send panel-generated messages with the panel Subscriber ID
number.
2
ND
CS ID
(12)
This must be programmed with a value, even if it is the same as the primary central
station. The alarm panel has the option to send a selected message to the second central
station.
REVIEW (Y/N)
(N)
Enter Y to review the programming options and to ensure that the correct responses have
been made. Parameters can be changed during review.
Enter N to end programming session.
Fire Display
RST FIRE PTN?.
If device type 8 (Fire Display) is selected, this prompt will appear.
Press 0 to disable FSA's Silence/Reset button (default).
Press 1 to enable FSA's Silence/Reset button to Silence the fire alarm system when
pressed once (Silence only).
Press 2 to enable FSA's Silence/Reset button to Silence and then Reset the fire alarm
system when pressed twice.
VIP Module and VISTA Gateway Module
MODULE PART.
If device type 5 (VIP Module) or type 9 (VGM) is selected, this prompt will appear. Enter
the partition number 1-2 in which the module is located.
Press [
✱
] to accept entry.
Press 00 + [
✱
] to exit Menu Mode.
Press
✱
99 to exit Program Mode.