010 ENTRY OR EXIT
0
If response type 27 selected, this prompt will be displayed. Enter whether the access point is
an entry or exit point.
0 = entry;
1 = exit
010 BELL/RLY SEL
0
Each zone can be assigned to activate either one or both bell outputs and/or the system's
auxiliary relay. Enter one of the following assignments:
0=none; 1=Bell 1; 2=Bell 2; 3=Bells 1 and 2; 4=Aux Relay; 5=Bell 1 and Aux Relay; 6=Bell 2
and Aux Relay; 7=Bells 1 and 2 and Aux Relay.
Press [
✱
] to continue.
010 V-PLEX RELAY?
1 = YES 0 = NO
If input type 6 was selected, this prompt is displayed. Enter 1 if using a 4101SN relay
module for this zone. Otherwise enter 0.
010 CONS ECP ADDR
(00-30)
01
If input type 09 was selected, this prompt is displayed. Enter the ECP address of the keypad
that is being used for entry/exit for this access point (00-30).
010 ACS ZONE #
(00-31)
01
If input type 10 was selected, this prompt is displayed. Enter the PassPoint ACS zone ID that
this VISTA zone maps to (00-31).
010 INPUT S/N:
L
AXXX-XXXX 1
Serial Number Entry and Loop Number Entry.
a. Transmit two open and close (or close and open) sequences. For a button-type transmitter,
press and release the button, wait approximately 4 seconds, then press and release the
button a second time.
OR
b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the
Alpha keypad. Then press the [
✱
] key, the cursor will move to the “L” position. You can edit
the loop number, if necessary. When the loop number is acceptable, press [
✱
].
OR
c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter
with several input loops).
Press [
✱
] to accept.
010 INPUT S/N:
L
A022-4064 1
The cursor will then move to the Loop column (L) with the previously entered/transmitted serial
number displayed.
Enter the loop number (refer to 5800 Series Transmitters Loop Designations
section).
To Delete an Existing Serial Number, enter “0“ in the loop number field. The serial number
will change to “0”s.
If “0” was entered in error, simply re-enter the loop number or press [#], and the serial number
will return to the display.
Press [
✱
] to accept.
010 INPUT S/N:
L
A022-4064 1
The system will then check for a duplicate serial/loop number combination.
If a duplicate serial/loop number combination is found, the keypad will emit a single long beep,
and display the serial number along with a “?” for the loop number, allowing you to re-enter the
correct loop number.
If the serial/loop number combination is not a duplicate in the system, a display showing the
serial number and loop number entry will appear.
Press [
✱
] to continue.