Operation by the Engineer
38
Submenu
“5=L240/B/BS”
In submenu
“5=L240/B/BS”
the setting unit (evaluation module L240/BS)
can be tested, without the Intrusion Alarm Panel being in the ready to set
state.
Test of an Evaluation Module L240/BS:
See product manual “SafeKey Evaluation Module L240/BS”.
L240/B/BS
On Test
Submenu
“6=System”
In submenu
“6=System”
a battery or power supply test can be undertaken.
1=Check Battery
2=PSU Voltage
Battery Test, after a short wait, the “All OK” message should appear.
Battery Test
All OK
The voltage should be greater than 14.2 V with a power supply unit test.
PSU Voltage
14.408V
7.1.4 Menu 04 “Change PIN”
Menu item “4=Change PIN”:
The factory Engineer PIN “000000” can be
changed to a 6-digit Engineer PIN code. The new Engineer PIN code may
not correspond with the management PIN code for the Evaluation Module
L240/BS. The factory set Engineer PIN code should be changed
immediately as it may be known to the users (e.g. from the manual).
Old PIN
Input PIN:
Enter the current Engineer PIN and press button
!
New PIN
Input PIN:
Enter the new Engineer PIN and press button
!
Re-enter PIN
Input PIN:
Enter the new Engineer PIN again and press button
!
Engineer-PIN
1 = Time/Date
2 = Tamp.Reset
3 = Test
4 = Change PIN
5 = Printer
6 = Service
7 = Remote
8 = Edit
9 = Cct Off