12.7.3 Access
Access can occur in the unset state:
1.
With keypad code
Enter a valid 6-digit key code.
2.
With chip key
Insert and remove a valid chip key once.
With a strike plate and door cylinder the coupling system is activated for 6
seconds. The door can be unlocked and opened with the exterior handle.
12.7.4 Personal attack
The entry of the keypad code “Personal attack” triggers a “Personal attack
alarm” independently of the state of the Intrusion Alarm Panel (transistor
output “PA” of the L240).
In the unset state, the strike plate will also enable access.
In the unset state, “Personal attack” is triggered and “Access” is allowed.
In the set state with VdS class A, after entry of the personal attack code a
“Personal attack” is triggered, the area is switched to unset and “Access”
allowed.
In the set state with VdS class B, after entry of the personal attack code a
“Personal attack” is triggered, but the area remains set. After insertion of
a chip key with unset authorization, the area is switched to unset and
“Access” allowed.
In the set state with VdS class C, the keypad code “Personal attack” is
the first condition for unset switching. After insertion of a valid chip key
(second condition) the unset switching occurs, a “Personal attack” is
triggered and access for opening the door is also enabled on the strike
plate.
The authorization “PA” can only be defined for a keypad code.