Bus Motion Detector
100
LED yellow
LED yellow – on/off
The yellow LED indicates the response of the passive infrared sensors and
further displays of the detector (see chapter 13.3).
LED green
LED green – on/off
The green LED indicates the response of the microwave sensors and further
displays of the detector (see chapter 13.3).
AM Sens.
AM Sens. – on/off
Increases the sensitivity of the anti-mask monitoring.
Fault
Fault – on/off
Transfers detector faults to the Intrusion Alarm Panel and displays them on
the keypads. If this function is deactivated, the state of the detector is
indicated by its own LEDs.
Undervoltage
Undervoltage – on/off
Transfers the undervoltage of a detector to the Intrusion Alarm Panel and
displays this on the keypads. If this function is deactivated, the undervoltage
of the detector is indicated via the red LED.
Anti stealth
Anti-stealth – on/off
Increases the sensitivity and evaluation of the passive infrared share of the
motion detector and thus detects objects or persons who have assumed the
approximate ambient temperature.
Log
Log – on/off
Activates the alarm log function of the detector. The alarm log is set if the
detector is triggered in the set state and indicates triggering after unset
switching via the red LED. Thus, you can recognise which detector has
triggered an alarm.
13.7 Walk test
The walk test function enables setting of the detection range of the motion
detector. The LEDs are activated even when they have been switched off in
the programming. After the walk test, the LEDs are returned to their previous
state. The alarm log is not deleted in this case.
The reset of the anti-mask monitoring also occurs with the walk test function.
Hereby, the detection range of the detector must be entered and you must
wait until the yellow LED switches off.
13.8 Delete
Before a motion detector is removed from the XIB bus, it must be deleted
from the keypad.
In the submenu select function “4=
Del XIB Det.
”:
1=Auto Add
2=Add XIB Det.
3=Edit XIB Det.
4=Del XIB Det.
Circuit
Number _ _ _
Select the corresponding circuit
Cct nn
4
= Confirm
Press button
!
to acknowledge