Bus Motion Detector
96
13.3 Description of the LEDs
The bus motion detectors feature up to three different LEDs (red, yellow and
green) depending on the type. All detectors do however feature a red LED
for alarm recognition. For indication of the anti-masking, the Passive Infrared
Detector IR/XC also features an additional yellow LED. The Dual Motion
Detectors EIM/XB and EIM/XC feature a yellow indicator LED for passive
infrared detection indication and PIR anti-masking monitoring as well as a
green LED for indication of microwave detection and microwave anti-
masking monitoring.
The LEDs are parameterised to “ON” as standard after commissioning can
be parameterised to “OFF” from the central panel.
The
VdS requirement
for LED parameterisation is described in chapter
13.9.
LED overview:
LEDs
Description
Red LED
Alarm
Yellow LED
Response of passive infra red sensors
Green LED
Response of microwave sensors
The states of the detectors are indicated via LEDs and are dependent on the
detector signals and settings.
State overview:
IR/XB
IR/XC
EIM/XB
EIM/XC
Function
red
red
yellow
red
yellow
green red yellow
green
Anti-mask calibration
1x/3s
.
1x/3.
1x/3s.
Teached-in
10x
10x
10x
10x
Low voltage
10x
10x
10x
10x
Alarm
On 3s.
On
3s.
On 3s.
On 3s.
Alarm memory
ON
ON
ON
ON
MW Alarm
On 3s.
On 3s.
MW detection
1x
1x
MW anti-mask
3x/s.
3x/s.
MW fault
ON
ON
PIR alarm
On 3s.
On
3s.
On 3s.
On 3s.
PIR detection
1x
1x
1x
1x
PIR anti-mask
3x/s.
3x/s.
PIR fault
ON
ON
ON
ON
10x
= LED flashes 10x
1x/3s. = LED flashes 1x every 3 seconds
3x/s. = LED flashes 3x per second
On 3s. = LED is on for 3 seconds
13.4 Commissioning and
addressing
The installation and connection of motion detectors is undertaken on the
panel with the power switched off.
Remove the detector cover screw on the front cover using a screwdriver.
Carefully remove the circuit board from the plug device.
Establish the cable entry and insert the XIB bus cable.
Provide the aperture of the position ring for the cover tamper contact
(only if cover tamper monitoring required).
Install the lower detector housing at a suitable bracket/position.