Operation by the Engineer
35
7
Operation by the Engineer
7.1 Functions
In access level 2, all the functions required by the Engineer during inspection
or maintenance of the panel can be found. After access, all other keypads
are inhibited.
Access is only possible from access level 1, i.e. a user must first of all gain
access to access level 1 with his user PIN, and then the Engineer can
access level 2 using his Engineer PIN.
Entering an incorrect Engineer PIN
After an invalid PIN has been entered three times, the keypad will remain
inhibited for about 10 minutes.
Important information for VdS certified systems
Programming options in the installation instructions identified with “
VdS
” may
not be used.
The VdS directive for planning and installation (VdS 2311) must be
observed.
The following points should be observed in accordance with the directive:
1. A printer may only be connected for service purposes.
2. Remote operation/programming via PC or modem is not permissible.
3. Intrusion alarm circuits with external setting may not have switch off
capability and may not be time delayed.
If some relays are programmed for alerting purposes on the personal attack
circuits, they must be set to pulse operation.
Engineer menu access level 2
Engineer-PIN (6-digit)
1 = Time/Date
2 = Tamp.Reset
3 = Test
4 = Change PIN
5 = Printer
6 = Service
7 = Remote
8 = Edit
9 = Cct Off
1 = Time
2 = Date
1 = Print
2 = Circuits
3 = Sounders
6 = System
5 = L240/B/BS
4 = Strobe
1 = Set Up
2 = Config
3 = Changes
5 = Key/Code
4 = Text
1 = Service Date
2 = Service Num
01 = Connection
02 = Operations
03 = Auth Code
04 = SiteID
08 = Subnet Mask
07 = Gateway IP
06 = Panel Port
05 = Panel IP
12 = GSR 4 S/N
11 = GSR 3 S/N
10 = GSR 2 S/N
09 = GSR 1 S/N
(menu items 05-12 only
with LAN connection)
11:30 08 Okt 2008
Int
Unset
without PIN
User-PIN (4-digit)
4
11
Edit menu
see chapter 8
1
3
5
6
7
8
Operation with code
(access level 1)
see chapter 6.3
(Operation without code
see chapter 0)
without PIN
1 = Int Set
2 = Cct Off
3 = Disp Cct Off
4 = Input PIN
5 = Disp CctFault
01 = Int Set
02 = Cct Off
03 = Disp Cct Off
04 = Change PIN
05 = Disp CctFault
06 = Test
07 = Alarm Counter
08 = Log
09 = Ext Set *
10 = Time/Date *
11 = Input Eng.PIN
12 = Tamp.Reset *
14 = Delete **
15 = Cancel Print
6 = Cancel Print