Installation
Instructions
17
Terminal
Designation
Function (delivery state)
Remark:
19 Relay
1
(NO)
Relay switches with external set
20 Relay
1
(NC)
CN14
21 Relay
1
(common)
External set
(P)
22 Relay
2
(NO)
23 Relay
2
(NC)
CN12
24 Relay
2
(common)
Walk test
(P)
Relay switches, if the walk test function on the
keypad has been activated
25
Internal buzzer (+)
CN9
26
Internal buzzer (
-
)
Switches with system interrupt, tamper alarm
(unset) and after unset, in order to draw
attention to a triggered alarm.
27 free
28
Strobe light (+)
CN16
29
Strobe light (
-
)
(Active 0V)
Switches with external alarm until reset. Fuse
FS3 800 mA quick-blow
30
Siren 1 (
-
)
(Active 0V)
31
Siren 2 (
-
)
(Active 0V)
CN19
32*
Siren 1 & 2 (+)
Switches with external alarm for the set alarm
time (180 seconds)
Fuse FS3 800 mA quick-blow
33
Comm fail fault
Connection of the fault relay of
the comm fault. Normally
connected with jumper to 0 V.
With an open contact on the comm (fault) of
the setting prevention
CN5
34
Comm fault alarm
(Negative
acknowledgement)
Connection of the alarm relay of
the comm fault. Only if the panel
is programmed for a silent alarm.
Normally connected with jumper
to 0 V.
Generates a local alarm, if the comm fault
could not issue a silent alarm.
35
Panel tamper (+)
CN24
36
Common (
-
)
Panel tamper of the central
enclosure
Unset:
Buzzer and internal alarm
internal set:
Buzzer and internal alarm
external set:
External alarm
+,-,A,B
External Bus (XIB)
CN13
For connection of keypads (1-7)
and bus modules
Fuse FS3 800 mA quick-blow
(not keypad 0)
CN11
+,-,A,B
Internal bus for
keypad 0 (service
keypad)
Connection of the engineer
keypad (address 0)
VR 1
Battery
charging
voltage
Factory setting 13.8 V at 20°C.
VR 2
Systems
voltage
Factory setting 14.0 V.
LK7
Temperature
sensor
For temperature dependent
charging voltage of the battery
The temperature sensor is connected as near
as possible to the batters with a cable tie.
CN7
+, -
Battery 2
CN15
+, -
Battery 1
AC
IN, IN
GND
approx. 20 V AC
from transformer
From the transformer and mains connection
with integrated fuse, 400 mA slow-blow.
CN8
42 Relay
(NC)
Permanent alarm relay
43
Relay
(NO)
44
Relay
1
(common)
Switches with local alarm until reset.
- On VdS systems, siren 2 must be supplied by terminal V+ (CN17 or 18).
-
The transistor outputs 1-8 are assigned in the delivery state with the functions of area 1 described in the table.
Note:
Output 1
“
Intrusion
” switches with an intrusion alarm from all areas
.
Output 2
“
Personal attack
”
switches
with an intrusion alarm from all areas.
It can be reprogrammed (output address 0).