Bus Motion Detector
97
Connect the XIB bus cable according to the connection schematic.
Put the circuit board back onto the plug strip.
Apply the panel supply.
13.5 Teaching in the first
detector
On the programming level (Engineer menu) select function
“16=XIB-
Detectors”
.
15=Defaults
16=XIB-Detectors
Select the function “
2=Add XIB Det.
” in the submenu.
1=Auto Add
2=Add XIB Det.
Assign the circuit.
Circuit
Number _ _
Wait for the “
Tamper XIB Det.
” on the keypad.
Cct xx
Tamper XIB Det.
Close the detector enclosure cover and tighten the fixing screw.
The red LED of the detector indicates by flashing ten times that the detector
has been teached-in, and that the corresponding detector has been
assigned. Furthermore, on the LCD keypad, teach-in is also acknowledged
and the type designation of the detector is displayed. Thereafter, automatic
calibration of the anti-masking monitoring is undertaken.
Please wait . . .
IR/XB
XIB Det Added
The detector is parameterised automatically as a simple circuit and the
circuit is assigned as an XIB detector as well as area 1. The parameters can
be subsequently modified in the programming level (Engineer menu) in the
submenu “
03=Circuits
”.
03=Circuits
04=Relay
Select the respective circuit in the submenu.
Circuit
Number _ _