Internal connection with blind output
Caution: Observe parametrization
of outputs!
Options:
No
AB
CD
EF
GH
IJ
KL
•
Output X (X = AB, CD, EF, GH, IJ, KL):
The binary output is connected directly with the Output X:
Blind. The
Input x: Blind sensor Blind UP/DOWN
(x = a…l) group object acts internally directly on the
Blind output X move UP/DOWN
group object. The
Input x: Blind sensor STOP/Slat adjustment
(x =
a…l) group object acts directly internally on the
Blind output X Slat adjustment/STOP UP/DOWN
group object.
This internal connection of the binary input with output A…L guarantees, for example, that pushbuttons for
operation of the blinds can be programmed and installed. This enables maximum flexibility in terms of blind
operation.
Operating functionality of blind
Options:
1 button op. (short = stepwise, long = move)
1 button op. (short = move,
long = stepwise)
1 button op. (move only - STOP)
1 switch operation (move only)
2 button op. (short = stepwise,
long = move)
2 switch/button operation (move only)
2 button operation (move only)
2 button operation (slat only)
Содержание i-bus KNX JRA/S 6.230.3.1
Страница 1: ...ABB i bus KNX JRA S 6 230 3 1 Blind Roller Shutter Actuator with Binary Inputs Product Manual ...
Страница 2: ......
Страница 8: ...ABB i bus KNX General 6 2CDC506083D0201 JRA S 6 230 3 1 ...
Страница 14: ...ABB i bus KNX Device technology 12 2CDC506083D0201 JRA S 6 230 3 1 2 3 Dimension drawing 2CDC072028F0016 ...
Страница 142: ......
Страница 148: ...ABB i bus KNX Appendix 146 2CDC506083D0201 JRA S 6 230 3 1 Notes ...
Страница 149: ...ABB i bus KNX Appendix JRA S 6 230 3 1 2CDC506083D0201 147 Notes ...
Страница 150: ...ABB i bus KNX Appendix 148 2CDC506083D0201 JRA S 6 230 3 1 Notes ...
Страница 151: ......