232 Parameters
When bit 0 of parameter
is
0 (Separate), selects a source that activates constant
frequency 3.
When bit 0 of parameter
is
1 (Packed), this parameter and parameters
and
select
three sources that are used to activate constant frequencies.
See table at parameter
For the selections, see parameter
Defines constant frequency 1 (the frequency the motor will
turn when constant frequency 1 is selected).
5.00 Hz
-500.00…500.00
Hz
Constant frequency 1.
See par.
Defines constant frequency 2.
10.00 Hz
-500.00…500.00
Hz
Constant frequency 2.
See par.
Defines constant frequency 3.
15.00 Hz
-500.00…500.00
Hz
Constant frequency 3.
See par.
Defines constant frequency 4.
20.00 Hz
-500.00…500.00
Hz
Constant frequency 4.
See par.
Defines constant frequency 5.
25.00 Hz
-500.00…500.00
Hz
Constant frequency 5.
See par.
Defines constant frequency 6.
40.00 Hz
-500.00…500.00
Hz
Constant frequency 6.
See par.
Defines constant frequency 7.
50.00 Hz
-500.00…500.00
Hz
Constant frequency 7.
See par.
Defines a safe frequency reference value that is used with
supervision functions such as
•
•
•
.
0.00 Hz
-500.00…500.00
Hz
Safe frequency reference.
See par.
No.
Name/Value
Description
Def/FbEq16
ACS580 FW.book Page 232 Wednesday, September 21, 2016 9:48 PM
Содержание ACS580 Series
Страница 88: ...84 ACS580 FW book Page 84 Wednesday September 21 2016 9 48 PM ...
Страница 146: ...142 Program features ACS580 FW book Page 142 Wednesday September 21 2016 9 48 PM ...
Страница 444: ...440 Fieldbus control through a fieldbus adapter ACS580 FW book Page 440 Wednesday September 21 2016 9 48 PM ...
Страница 461: ...ACS580 FW book Page 457 Wednesday September 21 2016 9 48 PM ...
Страница 462: ...3AXD0000016097 Rev D EN 2016 09 02 ACS580 FW book Page 458 Wednesday September 21 2016 9 48 PM ...