V6100 and V7122 User Guide
367
accepts and processes ‘get’ and ‘set’ requests. An EM can be used to configure up to 5
Trusted Managers.
If Trusted Managers are defined, all community strings work from all Trusted
Managers. That is, there is no way to associate a community string with particular
trusted managers.
Configuration of Trusted Managers via ini File
To set the Trusted Mangers table from start-up, write the following in the
ini
file:
SNMPTRUSTEDMGR_X = D.D.D.D
where X is any integer between 0 and 4 (0 sets the first table entry, 1 sets the second, and
so on), and D is an integer between 0 and 255.
Configuration of Trusted Managers via SNMP
To configure Trusted Managers, the EM must use the SNMP-COMMUNITY-MIB, the
snmpTargetMIB and the TGT-ADDRESS-MASK-MIB.
To add the first Trusted Manager:
(The following procedure assumes that there is at least one configured read-write
community. There are currently no Trusted Managers. The taglist for columns for all
srCommunityTable rows are currently empty).
1
Add a row to the snmpTargetAddrTable with these values: Name=mgr0, TagList=MGR,
Params=v2cparams.
2
Add a row to the tgtAddressMaskTable table with these values: Name=mgr0,
tgtAddressMask=255.255.255.255:0. The agent does not allow creation of a row in this
table unless a corresponding row exists in the snmpTargetAddrTable.
3
Set the value of the TransportLabel field on each non-TrapGroup row in the
srCommunityTable to MGR.
To add a subsequent Trusted Manager:
(The following procedure assumes that there is at least one configured read-write
community. There are currently one or more Trusted Managers. The taglist for columns for
all rows in the srCommunityTable are currently set to MGR. This procedure must be
performed from one of the existing Trusted Managers).
1
Add a row to the snmpTargetAddrTable with these values: Name=mgrN, TagList=MGR,
Params=v2cparams, where N is an unused number between 0 and 4.
2
Add a row to the tgtAddressMaskTable table with these values: Name=mgrN,
tgtAddressMask=255.255.255.255:0.
Содержание TP-1610
Страница 28: ...28 V6100 and V7122 User Guide Reader s Notes ...
Страница 48: ...48 V6100 and V7122 User Guide Reader s Notes ...
Страница 72: ...72 V6100 and V7122 User Guide Reader s Notes ...
Страница 80: ...80 V6100 and V7122 User Guide Reader s Notes ...
Страница 151: ...V6100 and V7122 User Guide 151 Figure 83 Log off Prompt 2 Click OK in the prompt the Web session is logged off ...
Страница 152: ...152 V6100 and V7122 User Guide Reader s Notes ...
Страница 262: ...262 V6100 and V7122 User Guide Reader s Notes ...
Страница 284: ...284 V6100 and V7122 User Guide Reader s Notes ...
Страница 291: ...V6100 and V7122 User Guide 291 Figure 95 V7122 Startup Process ...
Страница 324: ...324 V6100 and V7122 User Guide Reader s Notes ...
Страница 354: ...354 V6100 and V7122 User Guide Reader s Notes ...
Страница 374: ...374 V6100 and V7122 User Guide Reader s Notes ...
Страница 382: ...382 V6100 and V7122 User Guide Figure 130 Example of a User Information File Reader s Notes ...
Страница 392: ...392 V6100 and V7122 User Guide Reader s Notes ...
Страница 409: ...V6100 and V7122 User Guide 409 Reader s Notes ...
Страница 413: ...V6100 and V7122 User Guide 413 Reader s Notes ...
Страница 425: ...V6100 and V7122 User Guide 425 Figure 145 UDP2File Utility Reader s Notes ...
Страница 431: ...V6100 and V7122 User Guide 431 Reader s Notes ...
Страница 447: ...V6100 and V7122 User Guide 447 Reader s Notes ...
Страница 449: ...V6100 and V7122 User Guide 449 Figure 146 Connection Module CM Figure 147 OSN Server Figure 148 Hard Drive Module HDMX ...
Страница 483: ...V6100 and V7122 User Guide 483 Reader s Notes ...