3-3
After associating an isolate-user-VLAN with the specified secondary VLANs, you cannot add/remove a
access port to/from each involved VLAN or remove each involved VLAN. To do that, you must cancel
the association first.
Displaying and Maintaining Isolate-User-VLAN
To do...
Use the command...
Remarks
Display the mapping between an
isolate-user-VLAN and its secondary VLAN(s)
display isolate-user-vlan
[
isolate-user-vlan-id
]
Available in any view
Isolate-User-VLAN Configuration Example
Network requirements
z
Connect Device A to downstream devices Device B and Device C;
z
Configure VLAN 5 on Device B as an isolate-user-VLAN, assign the uplink port GigabitEthernet
2/0/5 to VLAN 5, and associate VLAN 5 with secondary VLANs VLAN 2 and VLAN 3. Assign
GigabitEthernet 2/0/2 to VLAN 2 and GigabitEthernet 2/0/1 to VLAN 3.
z
Configure VLAN 6 on Device C as an isolate-user-VLAN, assign the uplink port GigabitEthernet
2/0/5 to VLAN 6, and associate VLAN 6 with secondary VLANs VLAN 3 and VLAN 4. Assign
GigabitEthernet 2/0/3 to VLAN 3 and GigabitEthernet 2/0/4 to VLAN 4.
z
For Device A, Device B only has VLAN 5 and Device C only has VLAN 6.
Figure 3-2
Network diagram for isolate-user-VLAN configuration
GE
2/0
/1
GE
2/0
/2
VLAN 5
GE
2/0
/3
GE
2/0
/4
VLAN 6
GE2/0/5
GE2/0/5
Device A
Device B
Device C
Host A
Host B
Host C
Host D
VLAN 3
VLAN 2
VLAN 3
VLAN 4
Configuration procedure
The following part provides only the configuration on Device B and Device C.
1) Configure Device B
# Configure the isolate-user-VLAN.
<DeviceB> system-view
Содержание S7906E - Switch
Страница 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Страница 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Страница 494: ...ii Displaying and Maintaining Tunneling Configuration 1 45 Troubleshooting Tunneling Configuration 1 45...
Страница 598: ...ii...
Страница 1757: ...4 9...
Страница 1770: ...6 4...
Страница 2017: ...2 11 Figure 2 3 SFTP client interface...
Страница 2062: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2...
Страница 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...
Страница 2442: ...2 4 Set the interval for sending Syslog or trap messages to 20 seconds Device mac address information interval 20...