1-4
Receive control VLAN
The receive control VLAN is used for receiving and processing flush messages. When link switchover
occurs, the devices (such as Device A, Device B, and Device E in
Figure 1-1
) receive and process flush
messages in the receive control VLAN and refresh their MAC address forwarding entries and ARP/ND
entries.
Flush message
Flush messages are used by a smart link group to notify other devices to refresh their MAC address
forwarding entries and ARP/ND entries when link switchover occurs in the smart link group. Flush
messages are common multicast data packets, and will be dropped by a blocked receiving port.
How Smart Link Works
Link backup mechanism
As shown in
Figure 1-1
, the link on GE2/0/1 of Device C is the master link, and the link on GE2/0/2 of
Device C is the slave link. Normally, GE2/0/1 is in the forwarding state, while GE2/0/2 is in the standby
state. When the master link fails, GE2/0/2 takes over to forward traffic while GE2/0/1 is blocked and
placed in the standby state.
z
When a port switches to the forwarding state, the system outputs log information to notify the user
of the port state change.
z
To keep traffic forwarding stable, the master port that has been blocked due to link failure does not
take over immediately upon its recovery. Instead, link switchover will occur at next link switchover.
Topology change mechanism
As link switchover can outdate the MAC address forwarding entries and ARP/ND entries on all devices,
you need a forwarding entry update mechanism to ensure proper transmission. By far, the following two
update mechanisms are provided:
z
Uplink traffic-triggered MAC address learning, where update is triggered by uplink traffic. This
mechanism is applicable to environments with devices not supporting smart link, including devices
of other vendors’.
z
Flush update where a Smart Link-enabled device updates its information by transmitting flush
messages over the backup link to its upstream devices. This mechanism requires the upstream
devices to be capable of recognizing smart link flush messages to update its MAC address
forwarding entries and ARP/ND entries.
Role preemption mechanism
As shown in
Figure 1-1
, the link on GE2/0/1 of Device C is the master link, and the link on GE2/0/2 of
Device C is the slave link. Once the master link fails, GE2/0/1 is automatically blocked and placed in the
standby state, while GE2/0/2 takes over to forward traffic. During this period, if the smart link group is
Содержание S7906E - Switch
Страница 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Страница 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Страница 494: ...ii Displaying and Maintaining Tunneling Configuration 1 45 Troubleshooting Tunneling Configuration 1 45...
Страница 598: ...ii...
Страница 1757: ...4 9...
Страница 1770: ...6 4...
Страница 2017: ...2 11 Figure 2 3 SFTP client interface...
Страница 2062: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2...
Страница 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...
Страница 2442: ...2 4 Set the interval for sending Syslog or trap messages to 20 seconds Device mac address information interval 20...