1-4
z
Remote connection: A remote connection is established between a local CE and a remote CE,
which are connected to different PEs. In this case, a static LSP is required to transport packets
from one PE to another.
z
Only remote connection is supported by S7900E Series Ethernet Switches.
z
You must configure for each remote CCC connection two LSPs, one for inbound and the other for
outbound, on the P device along the remote connection.
SVC MPLS L2VPN
Static Virtual Circuit (SVC) also implements MPLS L2VPN by static configuration. It transfers L2VPN
information without using any signaling protocol.
The SVC method resembles the Martini method closely and is in fact a static implementation of the
Martini method. The difference is that it does not use LDP to transfer Layer 2 VC and link information.
You only need to configure VC label information.
The labels for CCC and SVC range from 16 to 1023, which are reserved for static LSPs.
Martini MPLS L2VPN
The key of the Martini method is to set up VCs between CEs. Pseudo wire that is the bidirectional virtual
connection between VSIs. A PW consists of two unidirectional MPLS virtual circuits (VCs).
Martini MPLS L2VPN employs VC type and VC ID to identify a VC. The VC type indicates the
encapsulation type of the VC, which can be VLAN,. The VC ID uniquely identifies the VC among the
VCs of the same VC type on a PE.
The PEs connecting the two CEs of a VC exchange VC labels through LDP, and bind their respective
CE by the VC ID.
Once LDP establishes an LSP between the two PEs and the label exchange and the binding to CE are
finished, a VC is set up and ready to transfer Layer 2 data.
To allow the exchange of VC labels between PEs, the Martini method extended LDP by adding the
forwarding equivalence class (FEC) type of VC FEC. Moreover, as the two PEs exchanging VC labels
may not be connected directly, a remote LDP session must be set up to transfer the VC FEC and VC
labels.
With Martini MPLS L2VPN, only PEs need to maintain a small amount of VC labels and LSP mappings
and no P device contains Layer 2 VPN information. Therefore, it has high scalability. In addition, to add
a new VC, you only need to configure a one-way VC for each of the PEs. Your configuration will not
affect the operation of the network.
Содержание S7906E - Switch
Страница 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Страница 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Страница 494: ...ii Displaying and Maintaining Tunneling Configuration 1 45 Troubleshooting Tunneling Configuration 1 45...
Страница 598: ...ii...
Страница 1757: ...4 9...
Страница 1770: ...6 4...
Страница 2017: ...2 11 Figure 2 3 SFTP client interface...
Страница 2062: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2...
Страница 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...
Страница 2442: ...2 4 Set the interval for sending Syslog or trap messages to 20 seconds Device mac address information interval 20...