4
12
QoS in an EPON System
When configuring QoS in an EPON system, go to these sections for information you are interested in:
z
QoS in an EPON System
z
Configuring QoS in an EPON System
QoS in an EPON System
An S7900E switch installed with an OLT card can work as an OLT in an EPON system. For detailed
information about an EPON system, refer to the
Introduction to EPON System
part in
EPON-OLT
Configuration
.
You can configure QoS for an OLT and ONUs attached to the OLT. To achieve QoS in an EPON system,
you must configure QoS at both the OLT side and the ONU side. The following part introduces QoS
functions that can be configured for uplink traffic and those for the downlink traffic.
QoS Functions for Uplink Traffic
Processing on an ONU
z
Configuring the priority trust mode for an ONU.
z
Configuring traffic classification for an ONU: the ONU classifies the uplink traffic of a UNI and
marks CoS precedence values for the matching traffic, so that traffic can be put into different
queues.
z
Filtering the packets matching certain match criteria according to the configured QoS policy.
z
Configuring the ONU to perform traffic policing for uplink traffic of a UNI.
z
Configuring the UNI to tag the uplink 802.1q-untagged traffic with the default VLAN tag, and adding
the UNI priority to the Priority field as the 802.1p precedence (CoS precedence).
z
Configuring the ONU to distribute the uplink traffic to different output queues based on the
mapping between the CoS precedence and local precedence.
z
Configuring the ONU to perform congestion management for traffic from uplink ports, supporting
SP and WFQ queue scheduling algorithms (available to only H3C ONUs).
Processing on an OLT
z
By default, an OLT port trusts the 802.1p precedence of the packets. You can configure to trust the
DSCP precedence of the packets through the command line. Thus, the OLT will obtain the CoS
precedence based on the mapping between the DSCP precedence and CoS precedence before
mapping the CoS precedence to the corresponding output queue. This configuration applies to all
uplink traffic of ONUs.
z
Configuring congestion management for uplink ports (supporting SP, WRR, and SP+WRR queue
scheduling algorithms).
z
Configuring congestion avoidance on an OLT. When the port is congested, received packets are
dropped selectively.
Figure 12-1
shows the QoS model for uplink traffic in an EPON system.
Содержание S7906E - Switch
Страница 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Страница 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Страница 494: ...ii Displaying and Maintaining Tunneling Configuration 1 45 Troubleshooting Tunneling Configuration 1 45...
Страница 598: ...ii...
Страница 1757: ...4 9...
Страница 1770: ...6 4...
Страница 2017: ...2 11 Figure 2 3 SFTP client interface...
Страница 2062: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2...
Страница 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...
Страница 2442: ...2 4 Set the interval for sending Syslog or trap messages to 20 seconds Device mac address information interval 20...