1-34
To do...
Use the command...
Remarks
Enter system view
system-view
—
Enter Ethernet
interface view, or
Layer 2 aggregate
interface view
interface
interface-type
interface-number
Enter interface
or port group
view
Enter port group view
port-group manual
port-group-name
Required
Use either command.
Enable No Agreement Check
stp no-agreement-check
Required
Disabled by default
No Agreement Check configuration example
1) Network
requirements
z
Device A connects to Device B, a third-party device that has different MSTP implementation. Both
devices are in the same region.
z
Device B is the regional root bridge, and Device A is the downstream device.
Figure 1-9
No Agreement Check configuration
2) Configuration
procedure
# Enable No Agreement Check on GigabitEthernet 2/0/1 of Device A.
<DeviceA> system-view
[DeviceA] interface gigabitethernet 2/0/1
[DeviceA-GigabitEthernet2/0/1] stp no-agreement-check
Configuring Protection Functions
An MSTP-enabled device supports the following protection functions:
z
BPDU guard
z
Root guard
z
Loop guard
z
TC-BPDU guard
Among loop guard, root guard and edge port settings, only one function can take effect on a port at the
same time.
Содержание S7906E - Switch
Страница 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Страница 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Страница 494: ...ii Displaying and Maintaining Tunneling Configuration 1 45 Troubleshooting Tunneling Configuration 1 45...
Страница 598: ...ii...
Страница 1757: ...4 9...
Страница 1770: ...6 4...
Страница 2017: ...2 11 Figure 2 3 SFTP client interface...
Страница 2062: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2...
Страница 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...
Страница 2442: ...2 4 Set the interval for sending Syslog or trap messages to 20 seconds Device mac address information interval 20...