background image

Type NR oil switch installation and operation instructions

COOPER POWER

SERIES

Oil Switches 

MN230008EN

Effective November 2016
Supersedes  October 2013 (S260-20-1)

Содержание NR

Страница 1: ...Type NR oil switch installation and operation instructions COOPER POWER SERIES Oil Switches MN230008EN Effective November 2016 Supersedes October 2013 S260 20 1...

Страница 2: ...ICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUME...

Страница 3: ...d storage 1 Description of operation 1 Check switch ratings prior to installation 1 Quality standards 1 RATINGS AND SPECIFICATIONS 2 INSTALLATION PROCEDURE 3 Check out procedure 3 Main wiring 3 Contro...

Страница 4: ...en working around high voltage lines and equipment and support our Safety For Life mission Safety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe persona...

Страница 5: ...ch 1 Inspect the switch thoroughly for damage and loss of parts or oil incurred during shipment If damage or loss is discovered file a claim with the carrier immediately 2 Check for oil leakage and ti...

Страница 6: ...Basic Insulation Level BIL kV 95 95 125 125 60 Hertz withstand voltage kV Dry one minute Wet ten seconds 35 30 35 30 42 36 60 50 Continuous current rating Amps 200 200 200 60 Load interrupting ability...

Страница 7: ...eration CLOSE and OPEN the switch contacts manually using the yellow operating handle Confirm that the contacts have closed and opened by listening for the sound of operation or by a continuity check...

Страница 8: ...n diagram for a standard three wire control is shown in Figure 2 NOTE G Ground 2 Close 3 Open MOTOR 0 1 G 2 3 4 Black Red AC White DC Black AC Black DC Red SEL SW NO MO C NC A B C Close Recaptacle ACC...

Страница 9: ...cally by applying rated control voltage to the proper terminals of the actuator terminal block If the switch actuator does not respond to an electrical operating signal it may be that the main switch...

Страница 10: ...capacity 1 1 2 gal 1 06 OPENING FOR FACTORY WIRED RECEPTACLE 44 HOLES 4 1 5 4 75 1 25 10 75 1 25 5 5 22 38 4 5 8 25 2 75 13 88 5 62 7 12 1 38 HOLE 8 0 2 0 14 25 7 88 8 SOLID TO 2 0 STRD BUSHING TERMI...

Страница 11: ...maintained it may fail to operate properly Maintenance manual Maintenance instructions for Type NR oil switch is provided in Service Information MN230001EN Reference TD280022EN provides information on...

Страница 12: ...188 United States Eaton com cooperpowerseries 2016 Eaton All Rights Reserved Publication No MN230008EN November 2016 SAFETY FOR LIFE Eaton is a registered trademark All trademarks are property of thei...

Отзывы: