1-14
Displaying and Maintaining PoE
To do…
Use the command…
Remarks
Display the mapping between ID,
module, and slot of all PSEs
display poe device
Display the mapping between ID,
module, and slot of all PSEs
(distributed IRF device)
display poe device
[
chassis
chassis-number
]
Display the power supply state of the
specified PoE interface
display poe interface
[
interface-type
interface-number
]
Display the power information of a
PoE interface(s)
display poe interface power
[
interface-type
interface-number
]
Display the power information of the
PoE power supply and all PSEs
display poe power-usage
Display the power information of the
PoE power supply and all PSEs
(distributed IRF device)
display poe power-usage
[
chassis chassis-number
]
Display the information of PSE
display poe pse
[
pse-id
]
Display the power supply states of all
PoE interfaces connected with the
PSE
display poe pse
pse-id interface
Display the power information of all
PoE interfaces connected with the
PSE
display poe pse pse-id interface
power
Display information of the PoE power
supply
display poe-power
Display information of the PoE power
supply (distributed IRF device)
display poe-power
[
chassis
chassis-number
]
Display the state information of the AC
input power supply
display poe-power ac-input
state
Display the state information of the AC
input power supply (distributed IRF
device)
display poe-power
ac-input
state
[
chassis chassis-number
]
Display the alarm information of the
PoE power supply
display poe-power alarm
Display the alarm information of the
PoE power supply (distributed IRF
device)
display poe-power
alarm
[
chassis chassis-number
]
Display the state information of the DC
output power supply
display poe-power dc-output
state
Display the state information of the DC
output power supply (distributed IRF
device)
display poe-power
dc-output
state
[
chassis chassis-number
]
Display the parameter values of the
DC output power supply
display poe-power dc-output
value
Display the parameter values of the
DC output power supply (distributed
IRF device)
display poe-power
dc-output
value
[
chassis chassis-number
]
Available in any view
Содержание S7906E - Switch
Страница 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Страница 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Страница 494: ...ii Displaying and Maintaining Tunneling Configuration 1 45 Troubleshooting Tunneling Configuration 1 45...
Страница 598: ...ii...
Страница 1757: ...4 9...
Страница 1770: ...6 4...
Страница 2017: ...2 11 Figure 2 3 SFTP client interface...
Страница 2062: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2...
Страница 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...
Страница 2442: ...2 4 Set the interval for sending Syslog or trap messages to 20 seconds Device mac address information interval 20...