Configuring the RMON Alarm Function
Configuration Prerequisites
z
If you need to configure that the managed devices send traps to the NMS when it triggers an alarm
event, you should configure the SNMP agent as described in
SNMP Configuration
in the
System
Volume
before configuring the RMON alarm function.
z
If the alarm variable is the MIB variable defined in the history group or the Ethernet statistics group,
you must make sure that the RMON Ethernet statistics function or the RMON history statistics
function is configured on the monitored Ethernet interface; otherwise, the creation of the alarm
entry fails, and no alarm event is triggered.
Configuration Procedure
Follow these steps to configure the RMON alarm function:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Create an event entry in the event
table
rmon event entry
-
number
[
description
string
] {
log
|
log-trap log
-
trapcommunity |
none
|
trap trap
-
community
} [
owner
text
]
Required
Create an entry in the alarm table
rmon alarm
entry
-
number alarm
-
variable
sampling
-
interval
{
absolute
|
delta
}
rising-threshold
threshold
-
value1
event
-
entry1
falling-threshold
threshold
-
value2
event
-
entry2
[
owner
text
]
Create an entry in the private
alarm table
rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-interval
{
absolute
|
changeratio
|
delta
}
rising-threshold threshold-value1
event-entry1 falling-threshold
threshold-value2 event-entry2 entrytype
{
forever
|
cycle cycle-period
} [
owner
text
]
Required
Use at least one
command.
z
A new entry cannot be created if its parameters are identical with the corresponding parameters of
an existing entry Refer to
Table 1-1
for the parameters to be compared for different entries.
z
The system limits the total number of each type of entries (Refer to
Table 1-1
for the detailed
numbers). When the total number of an entry reaches the maximum number of entries that can be
created, the creation fails.
Содержание S7906E - Switch
Страница 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Страница 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Страница 494: ...ii Displaying and Maintaining Tunneling Configuration 1 45 Troubleshooting Tunneling Configuration 1 45...
Страница 598: ...ii...
Страница 1757: ...4 9...
Страница 1770: ...6 4...
Страница 2017: ...2 11 Figure 2 3 SFTP client interface...
Страница 2062: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2...
Страница 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...
Страница 2442: ...2 4 Set the interval for sending Syslog or trap messages to 20 seconds Device mac address information interval 20...