ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
30
Confidential and Proprietary Information of ZTE CORPORATION
4.
Click a site, a cell, a carrier or a channel to be shown in the left
navigation tree, and the current status of the selected object will be
shown on the right list. See Figure 17.
F
I G U R E
1 7
D
Y N A M I C
D
A T A
S
T A T U S
D
I S P L A Y
[
Normal result
]
Status of the selected object is displayed in the interface.
[
Handling
]
Check whether the dynamic data of a carrier is abnormal. If not, perform
troubleshooting with reference to the handling methods of carrier faults in
Chapter 7.
[
Precautions
]
For more information about dynamic data status display, refer to
ZXG10-
BSS (V2.0) BS Subsystem Operation Manual.
Creating Daily Performance Report
[
Instruments and meters
]
Create a daily performance report in the performance management
interface at the OMCR client end.
[
Test procedure
]
1.
Double click to start the OMCR client-end application program.
2.
Enter the user name and password according to the screen prompt to
enter the OMCR main interface.