Chapter 5 - Alarms and Handling
Confidential and Proprietary Information of ZTE CORPORATION 101
3.
Cause
The chip is faulty; the clock is abnormal; there is phase difference from
that of the BSC clock, or the E1 line is not connected securely.
4.
Handling method
i.
Check the electrical connection performance of the E1 cable.
ii.
If the E1 cable is in good condition, plug the module securely and
reset it.
iii.
If the alarm persists, the E1 interface chip may be abnormal.
iv.
If the chip self-test is passed, start the E1 interface self-loop test
flow.
v.
If the E1 interface self-loop test is normal, it can be basically
considered that the transmission equipment is faulty.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
If the alarm does not appear frequently, it can be ignored.
ETRM Alarm
Dry Contact Alarm
1.
Description
The dry contact alarm happens.
2.
Related information
Alarm code: 0XF15~0XF20.
Alarm level: customized; for details, please refer to
ZXG10-BSS (V2)
BS Subsystem Operation Manual.
Alarm influence: customized; for details, please refer to
ZXG10-BSS
(V2) BS Subsystem Operation Manual.
Alarm unit location type: SITE.
3.
Cause
For details, please refer to
ZXG10-BSS (V2) BS Subsystem Operation
Manual
.