Chapter 5 - Alarms and Handling
Confidential and Proprietary Information of ZTE CORPORATION 95
Alarms of Communication Link to Main
Rack
1.
Description
Alarm happens with the communication link to the master rack.
2.
Related information
Alarm code: 0X1A15.
Alarm level: 3.
Alarm influence: the site cannot implement the data/software loading
or O&M and it works abnormally.
Alarm unit location type: SITE.
3.
Cause
The communication link from the rack to the master rack is faulty.
4.
Handling method
i.
Check whether the cables between the racks are connected
securely and whether the cables have been damaged. Correct the
faulty conditions.
ii.
Start communication self-test of the master/slave racks to
determine whether it is the problem with the CMM hardware or
software flow. Solve the possible problems.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.
Alarm with Communication Link between
Master Rack and Left/Right Slave Rack
1.
Description
Alarm happens with the communication link between the master rack
and left/right slave racks.
2.
Related information
Alarm code: 0X1A16, 0X1A17.
Alarm Level.
Alarm influence: SITE.