![Zte ZXG10 BS21 Maintenance Manual Download Page 126](http://html1.mh-extra.com/html/zte/zxg10-bs21/zxg10-bs21_maintenance-manual_940269126.webp)
ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
112
Confidential and Proprietary Information of ZTE CORPORATION
The parameter configuration is wrong.
4.
Handling method
Wait for 10 minutes. If the alarm is not recovered, reconfigure the
parameters at the background and synchronize them to the BTS. If the
fault persists, replace the ETRM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
Inconsistent Cell Parameter Configuration
1.
Description
The cell parameter configurations are inconsistent.
2.
Related information
Alarm code: 0X1B22.
Alarm level: 3.
Alarm influence: In general, the BSC background validates the data
before the synchronization. This alarm seldom happens because the
data will not be synchronized unless the validity check passes. It will
make the BTS unable to work normally.
Alarm unit location type: FU.
Internal handling flow: CMM tries to re-configure parameters.
3.
Cause
The cell parameter configuration is wrong, or conflicts with the
configuration of channel parameters and CIP parameters.
4.
Handling method
Wait for 10 minutes. If the alarm is not recovered, reconfigure the
parameters at the background and synchronize them to the BTS.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.
Inconsistent FUC Software Versions
1.
Description
The FUC software version is inconsistent.
2.
Related information
Alarm code: 0X1B23.
Alarm level: 3.