Chapter 5 - Alarms and Handling
Confidential and Proprietary Information of ZTE CORPORATION 113
Alarm influence: This ETRM cannot work normally.
Alarm unit location type: FU.
Internal handling flow: Download the latest FUC software version again.
3.
Cause
The FUC software version is loaded wrongly. If one is configured as
BCCH, the whole cell will be unable to work normally.
4.
Handling method
Reset the ETRM module. If the resetting does not work, replace the
ETRM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.
Inconsistent CHP Software Versions
1.
Description
The CHP software version is inconsistent.
2.
Related information
Alarm code: 0X1B24.
Alarm level: 3.
Alarm influence: The four DSPs of the CHP cannot work. If one is
configured as BCCH, the whole cell will be unable to work normally.
Alarm unit location type: FU.
Internal handling flow: Download the latest CHP software version again.
3.
Cause
The CHP software version is loaded wrongly.
4.
Handling method
Reset the ETRM module. If the resetting does not work, replace the
ETRM module.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
This alarm should be handled immediately.
Temporary No Response from FUC’s L3
Software
1.
Description
FUC’s L3 software does not respond temporarily.