![Zte ZXG10 BS21 Maintenance Manual Download Page 236](http://html1.mh-extra.com/html/zte/zxg10-bs21/zxg10-bs21_maintenance-manual_940269236.webp)
ZXG10 BS21 (V2.2) Compact Outdoor BTS for GSM Maintenance Manual
222
Confidential and Proprietary Information of ZTE CORPORATION
2.
Perform relevant tests with the GSM test card.
i.
Insert a GSM card into MEMORY CARD READER SLOT (17), turn off
the power of the spectrum analyzer and then restart it. After the
initialization of the spectrum analyzer, select the GSM MENU in the
SOFTKEY LABELS area, wait a while and then start the GSM-related
test.
ii.
Generally, the output waveform of the BTS TRU can be tested.
Note:
The maximum input power value of the HP8954E is 30dbm (1W), and the
signal being input into the spectrum analyzer should be less than this value.
Generally, the spectrum analyzer should be connected with the TRU output,
instead of being connected with the BRS PA directly,
iii.
When the TRU output characteristics are tested, menus in SOFTKEY
LABELS and SOFTKEY can be used to measure POWER, RAMP,
FRECENCY, AMPLD and BURST.
3.
Application descriptions of other related tests.
i.
To test the FM and AM modulation signals, the related test
functions in the MEAS/USER menu of the spectrum analyzer will be
used. You also can demodulate these signals to observe the audio
and video signals, or connect a HEADPHONE to monitor the voice.
ii.
For the use of the FFT (Fast Fourier Transform) to observe the
frequency spectrum and other related functions, please refer to the
user’s manual of the HP spectrum analyzer.
Antenna Feeder Tester (SITE
MASTER S332B)
In the GSM BS test, the antenna feeder analyzer Site Master S332B can be
used to test SWR (Standing Wave Ratio) and RL (Return Loss) of the
antenna system in a certain frequency band range. When the faults of the
antenna system are found, it also can be used to test the SWR or RL of
different locations of the whole antenna, to locate the faults (DTF
(Distance To Fault)), and the test result curve can be directly printed by
the printer in real time.
Procedure for Testing SWR
1.
Power on the device.
2.
Press MODE and select FREQ-SWR by UP, LEFT and right Enter
3.
Press F1 and F2 to select the frequency band to be tested.
4.
Press START CAL for zeroing before the test.
i.
Connect the short calibration terminal (OPEN) to RF/REFLECTION
on the backplane, and press ENTER.