Chapter 5 - Alarms and Handling
Confidential and Proprietary Information of ZTE CORPORATION 105
4.
Handling method
i.
Check whether the AEM configuration type matches the actual type.
If not, replace it in time.
ii.
If it does, check whether the AEM is plugged securely and powered
on. Check whether the backplane transmission is faulty, and
whether the ETRM collection circuit is faulty. Replace the related
cables or module if true.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
AEM Not-in-Position Alarm
1.
Description
AEM not-in-position alarm happens.
2.
Related information
Alarm code: 0X1ACF.
Alarm level: 2.
Alarm influence: Transmission will be affected.
Alarm unit location type: SITE.
Internal handling flow: The power amplifier is shut down and relevant
ETRM is disabled.
3.
Cause
AEM not-in-position alarm happens.
4.
Handling method
Replace the AEM module, and reset the ETRM that is connected with it.
5.
Verification
This alarm does not appear in the OMCR alarm interface.
6.
Precautions
None.
TPU’s CHP DSP0 Initialization Failure
1.
Description
TPU’s CHP DSP0 initialization fails.
2.
Related information
Alarm code: 0X1B04.
Alarm level: 3.